We replaced a 40 gal gas Rheem water heater that was about 10 years old. The hot water was not entirely clear so I decided it was time for a new one. Note that this Rheem had not once ever lost its flame to include during a 3 day power outage during a bad windstorm in Nov 06.
Lowes had a good selection and I chose the
Whirlpool because of the 12 year
warranty.
Lowes said it would take 5 days for the tank to arrive but it took about a month... but thats another story.
The Whirpool water heater (SG1J5040T3NOV) was installed Mar 07 by a contractor sent by Lowes. Installation went by fine. Not 10 minutes after he left, the flame went out. Ok no problem, its not rocket science to relight it so I did so. It went out 8 times that day. So many times that I left the metal shield off because I was having to relight it so often. It went out sometime during that night. In the morning, I relit it again so we could take showers. I had to literally babysit it and relight it constantly. There was so much condensation dripping on the burner that the flame was orange instead of blue. That morning, I also noticed the collar at the base that screens out bugs, had popped off.
I am no mechanical engineer but I have a fair amount of common sense and do many things around the house and repair my own vehicles. My thoughts were that the condensation dripping down from the flue was excesive and snuffed out the flame to include the pilot flame. I see it as a design flaw fixable by having a measure in place that protects the pilot and burner. The condensation dripping is an unavoidable action that occurs as the cold water in the tank raises in temp to a point where condensation will not occur. This dripping reoccurs whenever the tank is emptied of its hot water and filled with cold.
The 2nd posibility I thought of was that the burner was not getting enough air flow.